Unisolv-YD

Low-GWP Hydrofluoroolefin Specialty Fluid

Unisolv-YD is a hydrofluoroolefin specialty fluid developed for industrial applications requiring low global-warming potential, nonflammable performance, and controlled evaporation. It is a clear, colorless liquid composed of (E)-1-chloro-2,3,3-trifluoropropene.

Hydrofluoroolefin Low GWP Nonflammable
Chemical Family Hydrofluoroolefin
Boiling Point 54°C
Global-Warming Potential 1
Flammability Nonflammable

Product Overview

Unisolv-YD is a clear, colorless hydrofluoroolefin liquid with a weak odor and a boiling point of 54°C. The product is nonflammable and has a reported global-warming potential of 1 and ozone-depletion potential of 0.00002.

Its physical properties make it suitable for evaluation in selected industrial applications requiring a low-GWP specialty fluid. Suitability should be confirmed through process testing, materials-compatibility review, and application-specific evaluation.

Low Global-Warming Potential

The SDS reports a global-warming potential of 1, supporting evaluation in lower-impact industrial applications.

Nonflammable

The product itself does not burn and has no reported flash point.

Controlled Evaporation

A reported boiling point of 54°C supports evaluation in processes requiring relatively rapid fluid evaporation.

Industrial Product

Intended for professional and industrial use under properly controlled handling and ventilation conditions.

Application Evaluation

Unisolv-YD may be evaluated for selected industrial processes that require a nonflammable, low-GWP hydrofluoroolefin specialty fluid.

Industrial Process Fluids

Evaluation in controlled industrial systems requiring a volatile, nonflammable specialty fluid.

Replacement Evaluations

Assessment for applications seeking lower-GWP alternatives to legacy specialty fluids.

Materials Compatibility

Compatibility should be confirmed with metals, plastics, seals, elastomers, and process equipment before use.

Technical Guidance

Contact Unistar Chemical for product documentation, application evaluation, and compatibility questions.

Technical Specifications

The following values are reported in the current Safety Data Sheet and are provided as typical physical and chemical properties, not as guaranteed product specifications.

Product Name Unisolv-YD
Chemical Family Hydrofluoroolefin
Chemical Name (E)-1-Chloro-2,3,3-trifluoropropene
CAS Number 1263679-71-5
Composition 100%
Physical State Liquid
Appearance Colorless liquid
Odor Weak odor
Melting Point -82.3°C
Boiling Point 54°C
Flash Point No flash point
Autoignition Temperature 446°C
Explosion Range 7–14 vol% at 60°C
Vapor Pressure 32 kPa at 25°C
Vapor Density Greater than 1, air = 1
Specific Gravity 1.39
Water Solubility 5,960 mg/L at 20°C
Log Pow 1.9
Provisional Exposure Limit 250 ppm, 8-hour TWA
Ozone-Depletion Potential 0.00002
Global-Warming Potential 1

Environmental Profile

Unisolv-YD has a reported global-warming potential of 1 and an ozone-depletion potential of 0.00002. It is also classified as harmful to aquatic life, so release into drains, waterways, soil, or the surrounding environment should be prevented.

Waste fluid, cleaning water, and empty containers should be handled through an appropriately licensed industrial waste-disposal contractor in accordance with applicable regulations.

Safety and Handling Information

Unisolv-YD may cause drowsiness or dizziness. Avoid breathing vapors, mists, or sprays and use only outdoors or in a well-ventilated area. Vapor is heavier than air and may accumulate near floor level or in confined spaces.

Wear suitable protective gloves, protective clothing, and eye or face protection. Keep containers tightly closed, away from direct sunlight, sparks, flames, heat sources, strong acids, strong bases, oxidizing agents, and reactive metals.

Important: This page provides a general product overview and does not replace the Safety Data Sheet. Review the current SDS before handling, storing, transporting, or disposing of Unisolv-YD.

Technical Resources

Access product safety information or contact our team for technical data, application guidance, and compatibility support.

Safety Data Sheet

Review hazard information, handling requirements, exposure controls, physical properties, storage guidance, and disposal considerations.

Technical Data Sheet

Request detailed application information, compatibility guidance, and product-performance data from our team.

Need Help Evaluating Unisolv-YD?

Contact our team for technical documentation, compatibility questions, product availability, replacement guidance, or application support.